A 2D drawing carries only some of what a model needs. Everything it does not state is a setting: a yellow field that holds a standard value or a typical-practice guess, so you can see exactly what was assumed. You can ignore the yellow list: the defaults stay applied and the measurement is determined by them, but each one is listed, tagged, and never presented as the drawing's own statement. State a value and it is kept inside your drawing set as a marking (@DEFAULT=<key>,<value>, @BY=user); remove it and the default returns.

A. What you are asked to state (the facts a drawing cannot give)

Fact Where you state it Why a default would be wrong
Units of each sheet Units section (the file header is shown, never applied by itself) a wrong unit scales the whole model
Set name (e.g. SHED) and view / level of each sheet Sheets section; suggestions from the title text wait for your tick which plan is which storey
Plan level (e.g. 0) Sheets section defines the storey
Height datum per elevation: the z of a marked line (e.g. the plinth line is 0.6096 m = 2 ft above ground, read from the column detail) Metadata → elevation sheet → @Z no drawing says which line is the datum
Which layer is what (column, footing, grade beam, beam, wall-panel hatch, fan, net, door swing, truss bar, door frame) Layers section (one choice per layer and view) a layer name is not evidence of what is drawn
Body heights nothing draws (e.g. footing depth from a detail, beam depth range) Body heights section → @BODYZ no elevation shows a buried footing
Areas to leave out (e.g. an expansion-joint strip that looks like a beam) Exclude areas → @EXCLUDE the joint would become a false beam
A stated size where a label and the drawn length disagree (e.g. a beam drawn 10 in deep, labelled 12 in) Stated sizes section → @SIZE the label's number is used; you may correct it
A details sheet (optional): a sheet of notes and schedules with no body layers add it to the set; nothing to type its text states the concrete grade, casting ratios and the footing / column schedules; it is read, never guessed, and a column schedule's below-grade section replaces a typed setting
Building type (General or Farming Shed) Element defaults → Building type selects cited type-specific defaults
Anything in section B you know better Element defaults → type a value and Set the default is a guess or a standard value, not your fact

B. The defaults used when you state nothing

std = a value with a named source in this repository or the rate pack. guess = typical practice, to be confirmed. The list below is generated from modeller/element_defaults.json (the registry the Modeller reads); the Element defaults section in the editor shows the same rows with the value in force, highlights the ones used in your model, and tells you where each value came from (default, your choice, the drawing set, or the building type).

Setting Element Unit Default Kind Basis Offered choices
building.type Building text General guess the kind of building; it selects the type-specific defaults and organises the reference component library. A person states it (@DEFAULT=building.type,Farming Shed) General, Farming Shed
beam.depth IfcBeam m 0.45 guess section depth when no label or band gives it 0.3, 0.45, 0.6
beam.edge_tol IfcBeam m 0.006 guess two parallel lines count as a beam's edges when their spacing is within this of the label's width, and pieces on one line within this are one run (§D109) 0.006, 0.003
beam.label_reach IfcBeam m 2.5 guess how far from a beam's size label its two edge lines may run (§D109: one label was measured 2.3 m from its member). 0 = beams are not read from labels 2.5, 0
beam.span_split IfcBeam text label_midpoint guess labels of different marks along one pair of edge lines split it at the midpoint between them: the drawing does not state where one mark ends (§D109: 3 marks on one 42.565 m pair). 'one_body' = the first label takes the whole run label_midpoint, one_body
beam.width IfcBeam m 0.3 guess section width when no label or band gives it 0.2, 0.25, 0.3
gradebeam.depth IfcBeam m 0.3 guess grade beam depth 0.3, 0.45
gradebeam.width IfcBeam m 0.3 guess grade beam width when no label gives it 0.2, 0.3
steel.label_reach IfcBeam m 1.5 guess how far from a steel section label its member's line may run (§D109). 0 = steel is not read from labels 1.5, 0
steel.section_table IfcBeam text standard guess a UB label names a designation, not its web and flange. BS EN 10365 values taken from public references, not from the drawing and not checked against the standard itself (§D109). 'off' = a gap standard, off
bodies.touching_parts IfcColumn text one_body guess rectangles of one direction that touch along a side are the parts of one body: the 2 flanges and the web of a built-up steel section drawn as 3 loops (§D109). 'separate' = one body per loop one_body, separate
column.height IfcColumn m 3 guess storey height when no elevation gives it 2.7, 3, 3.6
column.size IfcColumn m 0.3 guess square section when a column symbol gives none 0.2, 0.25, 0.3, 0.4
column.top_under_beam IfcColumn text beam_above guess a column under a beam end carries it up to the beam's underside; an elevation may draw it short where a wall, a net or another sheet hides it (§D100: the shed's lines 36–41 drawn 1.52 m under beams at 3.10 m). 'as_drawn' keeps the drawn top and the gap shows as a load_path finding beam_above, as_drawn
column.z_from_plans IfcColumn text plan_levels guess a column with no elevation height and no @BODYZ runs from the lowest plan that draws it to the next plan level above the highest plan that draws it (§D109). 'off' = a gap, left out plan_levels, off
loops.skew_tol IfcColumn m 0.001 guess a closed loop of lines counts as square, in any direction, when its corners lie within this of a true rectangle in the frame of its own longest side (§D109: a CAD export is 0.05 to 0.1 mm off square, the snap tolerance is 0.01 mm). 0 = sheet-axis rectangles only 0.001, 0
synth.column.belowgrade.size IfcColumn m 0 guess 0 = not stated: no below-grade column is built; state the schedule's below-grade section (e.g. 0.3556 for 14 in)
synth.column.grade_to_base IfcColumn m 0.6096 guess grade to the column base (plinth): 2 ft, the datum read from a column detail
ceiling.thickness IfcCovering m 0.012 guess board thickness when a ceiling is implied 0.009, 0.012, 0.015
floorfinish.thickness IfcCovering m 0.02 guess floor finish thickness when implied 0.01, 0.02, 0.05
net.thickness IfcCovering m 0.005 guess netting sheet thickness; the area is drawn 0.002, 0.005, 0.01
curtainwall.mullion IfcCurtainWall m 0.05 guess typical mullion width 0.05, 0.06
door.height IfcDoor m 2.1 guess typical door set height; plans do not draw it 2, 2.1, 2.4
door.operation_standard IfcDoor text SINGLE_SWING_LEFT guess the running standard of a 2D set's doors whose operation the model does not state (F7 D18): the majority side of the building's stated single-swing doors; drawn yellow on A-DOOR-DFLT SINGLE_SWING_LEFT, SINGLE_SWING_RIGHT
door.tag_reach IfcDoor m 3 guess how far from a door's tag its swing arc may be, the leaf then taking the schedule row's width and height (§D109: measured up to 2.6 m). 0 = doors are not read from tags 3, 0
door.thickness IfcDoor m 0.04 guess typical leaf thickness for a leaf drawn as one line 0.04, 0.05
door.width IfcDoor m 0.9 guess typical single leaf; used only for a door tag with no drawn swing or gap 0.8, 0.9, 1
fan.blades IfcFan count 4 guess the drawing's rings give the housing and hub radii, not the blades; a propeller fan is drawn with this many radial paddles 3, 4, 5, 6
fan.depth IfcFan m 0.3 guess housing depth; the diameter is drawn 0.2, 0.3, 0.4
fan.housing_wall IfcFan m 0.02 guess the housing is a tube of the drawn outer radius; its wall is not drawn 0.01, 0.02, 0.03
footing.depth IfcFooting m 0.4 guess pad footing thickness 0.3, 0.4, 0.6
footing.length IfcFooting m 1.2 guess pad footing plan length when no schedule gives it 1, 1.2, 1.5
footing.width IfcFooting m 1.2 guess pad footing plan width 1, 1.2, 1.5
footing.z_from_plan IfcFooting text plan_level guess a footing-layer loop with no elevation height: top = the plan's level. One F mark inside = a pad, its thickness footing.depth; else a raft, thick by the labels inside it (mm TH, RAFT mm) or the raft around it (§D109). 'off' = a gap, left out plan_level, off
member.section IfcMember text (empty) guess a member whose label carries no section: empty = the most common section drawn on the same set for the same kind of member (load_summary.js, shown assumed); a label such as 1.5"x1.5"x1/4" Angle = that section; none = leave them unweighed
member.size IfcMember m 0.04 guess square envelope for a member with no label or size 0.04, 0.05, 0.075
profile.angle_heel IfcMember text lower guess which way an angle opens is not stated by a section label; the heel corner sits at the low side of the bar's normal (the b x b envelope is kept either way) lower, upper
profile.angle_mesh IfcMember text label guess a section bar whose label states one equal-leg angle (1.5"x1.5"x1/4" Angle) is built as that L section (t(2b-t) x length) instead of its b x b box; 'box' keeps the drawn prism label, box
section.spacing IfcMember text column pitch guess a section drawn once repeats at the column pitch from its cut column pitch, 2 x column pitch
pile.diameter IfcPile m 0.3 guess typical bored pile diameter 0.3, 0.45, 0.6
pile.length IfcPile m 12 guess no pile length is drawn on a layout 6, 12, 18
plate.thickness IfcPlate m 0.00635 std 1/4 in, the thickness the truss section's own label states (a plate with no label takes it) 0.00476, 0.00635, 0.0095
railing.height IfcRailing m 1 guess typical guard height 0.9, 1, 1.1
railing.post_spacing IfcRailing m 1.2 guess typical post spacing 1, 1.2, 1.5
ramp.slope IfcRamp ratio 0.0833 guess 1:12, a typical accessible ramp 0.0625, 0.0833, 0.1
roof.from_spots IfcRoof text read guess a surface through the plan's TOS spot levels, inside what the spots reach; deck thickness and height over the steel from the sheet's own deck note (§D109). Not the roof's outline: nothing states its edge. 'off' = none read, off
roof.slope_deg IfcRoof deg 15 guess typical light roof pitch; used only when no gable or section gives the slope 10, 15, 17.5, 22.5
synth.roof.overhang IfcRoof m 0 guess the roof is cut at the gable planes until an overhang is stated 0, 0.4572, 0.6
synth.roof.sheet_thickness IfcRoof m 0.0254 guess display thickness of a roofing sheet (1 in); the cost is by area. The own weight is by area too, read off the sheet's plan box, which this thickness widens by thickness x sin(slope): a small weight change, no cost change 0.0254, 0.05
slab.edge_arc_sagitta IfcSlab m 0.005 guess an arc in a slab edge is read as straight facets no further than this from the arc (5 mm: under the reader's thinnest wall and the plank keyway) 0.002, 0.005, 0.01
slab.edge_joint_close IfcSlab m 0.05 guess §D70.1 the plan's slab edge closes gaps and notches narrower than this (plank / modelling joints are not drawn: hollow-core joints are grouted monolithic, the open keyway about 3/4 in, Oldcastle Hollowcore Plank Pocket Guide 2019); 0.05 m = the reader's thinnest wall (CFG wall.min_thickness), measured joints <= 24.9 mm (JKR), the first wall gap 60 mm (HHS)
slab.edge_void_min_area IfcSlab m2 0.0645 guess §D70.1 a hole in the slab is drawn as an opening when at least a 254 mm (10 in) square: the producer shows openings larger than 10 in square on shop drawings, smaller ones are core-drilled in the field (Oldcastle Hollowcore Plank Pocket Guide 2019); a hole a column or wall drawn on the same plan fills (>= 0.9) is that element, never an opening
slab.ground_on_raft IfcSlab text read guess a raft holding an S.O.G-mm label of a plan carries a ground slab on its own outline, n thick (§D109: the drawing states the thickness, not the slab's edge). 'off' = no such slab read, off
slab.level_step_min IfcSlab m 0.1 guess slab tops closer than this are one level (the measured finishes are 25-50 mm); a step of this size or more is drawn as its own piece with its own top and thickness (A-FLOR-OTLN elevation / thickness, A-FLOR-LEVL line); 1 or more = one level per storey 0.05, 0.1, 0.2, 1
slab.outline_when_not_rect IfcSlab text walls_bounded guess when the walls do not draw a rectangle, the slab is the area they bound on both axes (best effort, amber; HHS -10% against the model's floor slabs, a rectangle +163%); 'none' leaves the slab out and lists it walls_bounded, none
slab.underside_when_stepped IfcSlab text longest_cut guess when the section's slab under a level steps (finish on planks, a dropped wet area), the underside is the stack bottom under the longest cut (best effort, amber; JKR with STR: 84.33 under 77% of the cut); 'none' leaves it a conflict longest_cut, none
synth.slab.footprint IfcSlab text outermost grid lines guess the slab edge is taken at the outermost grid lines of the base plan outermost grid lines
synth.slab.thickness IfcSlab m 0.25 guess a guess: no sheet states the slab thickness. 250 mm is the slab line every rate pack's class table names ('RC Slab 250mm', the same 250 mm in all 16 country packs), a priced item, not a design value for this building (§D99) 0.15, 0.2, 0.25
stair.going IfcStair m 0.25 guess typical tread depth 0.25, 0.28, 0.3
stair.riser IfcStair m 0.175 guess typical riser height; a stair symbol carries no riser 0.15, 0.175, 0.19
stair.width IfcStair m 1 guess typical flight width 0.9, 1, 1.2
stair.flights IfcStairFlight text read guess 3 or more parallel lines of one length, evenly spaced, are a flight's nosings; rise = (0.63 - tread) / 2, the drawing states no riser; a flight narrower than 0.6 m is no flight (§D109). 'off' = no flights read, off
panel.plane IfcWall text grid family end line, centred guess an elevation panel is placed on an end grid line of its face, centred. An elevation whose grid labels share one family (AA, AB or A1 = family A; a label of one character or digits only has none) uses that family's end line, so a set of several wings keeps each elevation on its own wing (§D107); set back to the plan's outermost line with 'end grid line, centred'. @PLANE= on the sheet wins over both grid family end line, centred, end grid line, centred
wall.band_gap IfcWall m 0.35 guess parallel wall lines closer than this are one wall, solid from outer line to outer line: with no wall type schedule a leaf cannot be told from a cavity (§D109: spacing peaks at 50 to 300 mm). 0 = walls are not read from their lines 0.35, 0
wall.base IfcWall m 0 guess floor level of the storey
wall.height IfcWall m 3 guess typical storey wall height; not stated by a plan 2.4, 2.7, 3, 3.6
wall.min_thick IfcWall m 0.05 guess a band of wall lines thinner than this is a finish line, not a wall (§D109: 28 pieces measured 10-20 mm). 0 = read them as walls 0.05, 0
wall.tag_reach IfcWall m 1.5 guess how far a wall tag may lie from the wall it names, on a plan layer typed walltag: the nearest wall of that plan's level takes the tag as its type name. The binding is by distance, not checked; a name, not a build-up, without the wall type schedule (§D110). 0 = no tag is read 1.5, 0
wall.thickness IfcWall m 0.15 guess a guess: no sheet states the wall thickness. 150 mm is the wall line every rate pack's class table names (the same 150 mm in all 16 country packs), a priced item, not a design value for this building (§D99) 0.1, 0.115, 0.15, 0.2, 0.225
wall.top_from_elevation IfcWall text read guess a wall on the grid line an elevation stands on takes its top and base from that elevation's wall lines over its own span; other walls of that wing no higher than the wing's top (§D110). 'next_plan_level' = every wall stops at the next plan level read, next_plan_level
wall.top_when_unseen IfcWall text slab_above guess a wall no elevation shows runs from its floor to the slab underside above (the section states it); HHS Level 2 / 3 = the model, Level 1 0.3 m above the model's (its walls stop at a ceiling the drawings do not show); 'none' leaves such walls as asks slab_above, none
type.size_tie IfcWindow text library_first guess a size the library answers with several types (Duplex 819 x 759: SMALL_FIXED, CASEMENT) binds the library's first row (8 of the Duplex IFC's 12 are that type); an explicit binding or label always wins; 'none' leaves such fills as asks library_first, none
window.height IfcWindow m 1.2 guess typical window height 1, 1.2, 1.5
window.sill IfcWindow m 0.9 guess typical sill height above the floor 0.9, 1, 1.1
window.width IfcWindow m 1.2 guess typical window width; used when a plan symbol gives no width 0.9, 1.2, 1.5
check.set Set text read guess which printed relations the set check judges (§D112). A rule names its columns by heading; the tolerance is the printed rounding. 'off' = no sum is judged; add a row to judge another relation read, off
gate.unplaced_sheet Set text refuse guess a sheet the reader cannot place refuses the whole set, so nothing is converted past a sheet you meant to be read. 'set_aside' = the rest converts, each such sheet a counted gap with the reader's reason (§D110) refuse, set_aside
guide.gap_sheets Set text read guess which sheet of the set's own register might close each gap, by the words of its title; it says a sheet might help, never that it will (§D110). 'off' = no guide read, off
read.tables Set text read guess how a ruled schedule is told from other linework and how its heading is told from its rows (§D111). Fractions of the table's own cells or columns; 'off' = no table is read read, off
suggest.title_layout Set text read guess a title ending LAYOUT names a plan, as a title ending PLAN does (§D110). 'off' = no view is read from it, and the sheet refuses the set read, off
analytical.node_snap analytical m 0.25 guess ends closer than this are one joint in the analytical model (§D103): a beam drawn to a column face and a column top under the beam's axis are one joint; too small leaves joints open (dangling ends), too large merges separate joints 0.05, 0.1, 0.15, 0.25, 0.4
analytical.support analytical text FIXED guess a footing is assumed to restrain the column base; the engineer confirms (FIXED = no translation or rotation, PINNED = no translation) FIXED, PINNED
load.rc_steel_percent load % by volume 1 guess main reinforcement not drawn; BNBC 2012 Table 2.2.1 note: "for reinforced concrete, add 0.63 kN/m3 for each 1% by volume of main reinforcement" 0.5, 1, 1.5, 2, 3
load.roof_sheet load kN/m2 0.096 guess sheet thickness not drawn; BNBC 2012 Part 6 Ch 2 Table 2.2.2 "Steel, galvanized std. corrugated sheeting (incl. lap and fastenings) 0.8 mm thick 0.096" 0.077, 0.096, 0.12
load.unit_weight.brick load kN/m3 18.9 std BNBC 2012 Part 6 Ch 2 Table 2.2.1: "Brick 18.9" (modeller/reference/BNBC2012_P6C2_dead_load_tables.txt)
load.unit_weight.concrete load kN/m3 22.8 std BNBC 2012 Part 6 Ch 2 Table 2.2.1: "Concrete - stone aggregate (unreinforced) 22.8" (modeller/reference/BNBC2012_P6C2_dead_load_tables.txt)
load.unit_weight.steel load kN/m3 77 std BNBC 2012 Part 6 Ch 2 Table 2.2.1: "Steel 77.0" (modeller/reference/BNBC2012_P6C2_dead_load_tables.txt)
suggest.elev_no_grid suggest text centre_on_wing guess an elevation that names its grid line but draws no grid: centred along that line on the span of its wing, tinted and said so; its heights stay read (§D108: best-effort shape). 'lie_flat' = it stays as drawn centre_on_wing, lie_flat
suggest.grid_along suggest m 0.5 guess how far sideways a grid label's text position may sit from its line: CAD anchors a text at its corner, not its bubble's centre (measured 0.25 to 0.37 m on a Revit-exported plan, §D107); the nearest label still wins. 0.06 = the earlier value 0.06, 0.5
suggest.grid_label suggest text letters_digits guess the labels read from a grid line's end: A, AA, 12 and also A1, B12 (§D107: 10 of 29 labels of a Revit-exported plan). 'letters_or_digits' = the earlier grammar letters_digits, letters_or_digits
suggest.grid_layer suggest text name_has_grid guess layers searched for grid lines: any layer whose name holds GRID (a line with no label proposes nothing, so the name alone decides nothing, §D107). 'a_grid_only' = the template's layer and the layers you typed as grid name_has_grid, a_grid_only
suggest.grid_reach suggest m 1.2 guess how far beyond a grid line's end its label may sit: a bubble's centre at 1:100 (measured 0.809 to 1.022 m on a Revit-exported plan, §D107). 0.7 = the earlier reach 0.7, 1.2
suggest.grid_rotated suggest text read guess a grid line off the sheet axes with its label at one end is read as a plan grid line in its own direction (@GRIDA, §D108). 'off' = only counted read, off
suggest.grid_ticks suggest text unless_stated guess grid lines guessed from dimension ticks: not on an axis where the sheet states or reads 2 or more grid lines, and not outside its @REGION (§D107: a stated plan was given wall tags as grids and an elevation landed 72 m away). 'always' = the earlier behaviour unless_stated, always, off
suggest.level_footing suggest text read guess a plan no title or level name places takes its level from one distinct T/FOOTING value on the sheet: T/FOOTING: -1.250 m (§D109). 'off' = no such row read, off
suggest.level_name suggest text read guess a plan's level is read when its title and an elevation's level name agree: LEVEL 1 PLAN with LEVEL 01 beside EL: +4.800 m (§D108). 'off' = no such row read, off
suggest.level_text suggest text value_on_line guess a level datum is read from a TEXT or MTEXT such as +4.00 m or EL: +4.800 m when a horizontal line lies at exactly that height, on any layer; the value and the line are two separate facts that must agree (§D107). 'level_layer_only' = the earlier rule value_on_line, level_layer_only
suggest.sheet_refs suggest text report guess sheet numbers the set refers to but does not hold are listed as an advisory; it never blocks (§D107). 'off' = no list report, off
suggest.title_text suggest text text_and_mtext guess a sheet's role is read from TEXT and MTEXT titles; a note (a comma, or SEE / REFER) is not a title, and two spellings of one title are one (§D107). 'text_only' = the earlier rule text_and_mtext, text_only

Rule of resolution, strongest first: the drawing set's @DEFAULT marking → a choice made in the editor → the building type's cited override → the registry value above. A typo in a key is an error, never a silent default; a value that is not a non-negative number is refused and the default is used.

C. Building type: Farming Shed

Stating building.type = Farming Shed switches on cited values (sources: the TNAU poultry-house construction guide, and a Bangladesh agricultural-university broiler-shed lecture; both medium confidence):

Setting Value Basis
door.height 1.83 Farming Shed: preferred door 6 x 2.5 ft opening outward (TNAU)
door.width 0.762 Farming Shed: preferred door 6 x 2.5 ft (TNAU)
synth.roof.overhang 1.0668 Farming Shed: roof overhang at least 3.5 ft to keep rain out (TNAU)

It also lists the components a farming shed is expected to contain (fans, nets/pads, doors, roof, slab) and the typical ranges used for the Typology advisories (open-sided width 15–25 ft, environment-controlled 40 ft and wider, eave 6–7 ft, centre 10–12 ft). Advisories compare and never change a body or a setting; a missing expected part is reported, never invented (an evaporative pad with no drawn length is not built).

D. What Complete the building adds (amber, estimated)

Ticking Complete the building adds a floor slab and the gabled roof the drawings imply, and, where a column schedule states a section below grade, the below-grade column parts (footing top to grade at that section, grade to the base at the column's own section; synth.column.*). They are computed from drawn evidence plus the stated conventions synth.slab.* and synth.roof.* above, shown amber (derived), and their defaults are listed in yellow.

E. How evidence is shown

Evidence Meaning Where you see it
drawn measured from the drawing no mark
derived (amber) computed from drawn evidence plus a stated convention (slab, roof, a panel that inherits a thickness label, a stated beam range, fans, nets, door swings) Evidence colours checkbox on the import panel; Provenance = derived in the database
assumed (red) no drawing evidence for the body's existence or position (e.g. a truss section drawn once, repeated along the building) same checkbox; Provenance = assumed
yellow row a value the drawing did not state and a default supplied Metadata panel → All defaults; Accept all, or ignore

By default the canvas shows each body in its material's standard colour (display convention, not a measurement): reinforced concrete grey, brick masonry brick red, profiled metal roofing light blue-grey, netting green, steel sections and plates dark blue-grey, extraction fans and door sets their own colours. A material with no colour in the palette is shown neutral grey and listed.

F. Items the shed drawings left open (carried as yellow rows, never decided in code)

Item State
Truss spacing; whether the right half repeats the left assumed: a truss at every column line (red), section.spacing
Roof sheet thickness and overhang defaults 0.0254 m and 0 (synth.roof.*), overhang 1.0668 m under Farming Shed
Floor slab thickness and extent 0.25 m (rate-pack standard), outermost grid lines
Fan depth; netting thickness 0.3 m; 5 mm (the areas are drawn)
Door leaf thickness 0.04 m for a leaf drawn as one line (two drawn lines give the real thickness)
Door height drawn when the elevation's door-frame layer is typed (96 / 94 in on the shed), else 2.1 m
Four unlabelled 21.7 in swings with no open leaf listed, not built (they sweep 75°, not a door's quarter turn)
Evaporative pads not built: labelled, but no outline or length is drawn
False ceiling, slats (cross-section) not built: labelled on the section, no closed plane, size or spacing is drawn
Polythene and compacted sand under the slab not built: labelled, no thickness stated
Footing top: the detail section sums footing top to plinth to 84 in, the stated footing height (@BODYZ) puts it 69 in below the plinth the stated value is kept; the 15 in difference is listed here
Beam reinforcement not read: bars are labels on the section drawings, not a schedule (only the footing and column schedules are read)
24 in "support wall" text against the 96 / 98 in brick drawn on the elevations both kept; the brick is built as drawn
A beam drawn 10 in deep but labelled 12 in conflict row; the label's number is used